Open menu
EPANEL
PWT series PE pump built-in sewage lift double pump structure display

EPANEL · PWT Series / INTEGRATED LIFTING SYSTEM

PE pump built-in
sewage lifting station。

Let every space feel comfortable and upward.

Integrated PE box with built-in submersible sewage pump and automatic control.
Provide reliable sewage lifting solutions for spaces that cannot be drained by gravity.

Explore products below

PE integrated box Built-in submersible sewage pumpAutomatic control system

Box volume range

60–500L

Five levels of volume · Configurable on demand
Series flow range

6–35m³/h

Match different drainage needs
Series head range

10–30m

Coping with the improvement of underground space
Applicable medium temperature

≤40°C

Domestic sewage · pH 4–10

* The flow rate and head are the ranges of different configurations of the series and are not achieved at the same time under the same working conditions. Model selection needs to be based on actual flow, head and pipeline conditions.

01 / PRECISION INSIDE

strong,Comes from within.

Leave the complexity to the system.
Leave space for calmness.

PWT / DUAL PUMP SYSTEM Section of PE sewage lifter: double pumps inside the box, water outlet pipeline and blue check valve on the top
Click on the blue hotspot to learn more

BUILT FOR DEPENDABILITY

01 / Built-in dual pumps

Two motivations.
A calmness.

The built-in submersible sewage pump is integrated into the box. The dual-pump configuration supports alternate operation and standby switching, and cooperates with automatic control to cope with daily drainage needs.

Double pump alternatingFault alarmautomatic control

Dual pump structure diagram; actual pump type, accessories and control scheme are subject to the selected configuration.

01Cutting submersible sewage pumpDeal with domestic sewage calmly

A submersible sewage pump with cutting function can be configured. The pump type should be selected according to the medium and working conditions, and cannot replace the management of prohibited discharge of debris.

02Automatic control systemRunning status, orderly control

The supporting control system supports automatic operation, fault alarm and manual emergency operation; the dual-pump configuration can realize alternate operation and standby switching.

03Integrated compact layoutCreate possibilities for more space

Integrate the water collection tank, pump set and pipelines into an integrated arrangement. A maintenance space still needs to be reserved around the equipment, and construction and installation must be determined based on site conditions.

02 / FIND YOUR CAPACITY

Every kind of space.
All have suitable capacities.

From compact homes to commercial locations,
Use actual working conditions to find the appropriate configuration.

PE sewage lift series product appearance display

PE pump built-in series Product appearance diagram, non-capacity size comparison

YOUR CONFIGURATION

250L

PE sewage lifting station with internal pumps

Flow range
7–25 m³/h
Lift range
10–22 m
Power range
1.1–2.2 kW
Length × Width × Height
868 × 662 × 753 mm
Consult this volume plan

Series specifications are clear at a glance.

Configuration range of PWT series grouped by cabinet volume
Volume/LFlow / m³/hLift/mPower/kWOverall dimensions/mmVoltage/Vwater inletwater outlet
60 ●6–1010–150.75–1.1548 × 420 × 555220 / 380DN100DN50
90 ●6–1510–150.75–1.1562 × 464 × 630220 / 380DN100DN50
150 ●7–1515–201.1–2.2682 × 544 × 700380DN100DN50
250 ●7–2510–221.1–2.2868 × 662 × 753380DN100DN50 / DN65
500 ●15–3514–301.5–5.51010 × 800 × 900380DN100–150DN50 / DN65

Data source: "Grease Separator and Sewage Lifting Product Catalog" PWT Pump Built-in Series (printed pages 11–12). Each item in the table is a range of different configurations, and does not mean that any parameters can be freely combined; the actual working point, number of pumps and power supply requirements are subject to the final selection confirmation form.

03 / MORE POSSIBILITIES BELOW

Expand space downwards.
Upward promotion is possible.

invisible system,
Support visible comfort.

Installation instructions for bathroom underground equipment pit: PE sewage riser is connected to the water inlet pipe and vertical outlet pipe
INSTALLATION VISUALIZATION Installation effect diagram

BELOW THE SURFACE

Let the underground space
No more drainage restrictions.

When domestic sewage cannot be discharged by gravity, PWT collects it centrally and lifts it for transportation, providing drainage ideas for underground toilets and other spaces.

villa residencehotel clubpublic restroomcommercial space
Installation and media considerations

Suitable medium temperature is no higher than 40°C, pH 4–10. Oily kitchen wastewater must be treated with oil separation first; bath drainage must be protected by hair interception. Inspection space, ventilation, pipeline backflow prevention, etc. must be confirmed by professionals according to project conditions.

04 / PRODUCT PHOTOS

Product photos, details are visible.

From the whole to the details, get a closer look at the product.
Click on the image to enlarge it.

Real photography · 8 ZhangSingle-outlet and double-outlet models are displayed from multiple angles. The specific configuration is subject to the selection confirmation form.

Automatic scrolling display

EPANEL · PROFESSIONAL SUPPORT

Accurate selection for your project.

Tell us the drainage volume, lifting height and installation space,
Work together to determine a more appropriate PWT configuration.

Contact EPANEL · Get selection support 0551-63360583

Current intentions:250 L·PWT pump built-in series

Current selection information

Please copy the following content and send it to the EPANEL selection personnel.