Open menu
EPANEL
Skip to product content

EPANEL / WATER SUPPLY SYSTEMS

No negative pressure
Frequency conversion water supply

Frequency conversion and voltage stabilization, water supply on demand.

Integrate the water supply pump unit, frequency conversion control and pipeline system into a complete set to respond to water demands at different times, allowing orderly coordination of pressure supply regulation and equipment operation.

Stable pressure water supply / intelligent linkage / complete set delivery

PRODUCT IN FOCUS product rendering
Overall rendering of a complete set of variable frequency water supply equipment: dual pumps, control cabinet and diaphragm pressure tank
01 / EQUIPMENT OVERVIEWComplete equipment · Rendering diagram
01 Stable pressure supply
Adjust the operation of the pump unit around the set pressure.
02 Adjust as needed
Coordinate output with demand as water use changes.
03 Integrated package
Coordinated layout of pump units, controls and pipelines.

01 / SYSTEM COMPOSITION

Water supply system, complete set of coordination.

From pump set to control,
Connect equipment configuration with project requirements.

01 / PUMP SET

Water supply pump set

Combine the design flow, head and operating conditions to configure the number of water pumps and their operating combination.

02 / CONTROL

Frequency conversion control

Link pressure feedback with frequency conversion regulation to coordinate water pump operation and system pressure supply.

03 / PIPEWORK

Pipeline assembly

Coordinate the inlet and outlet pipes, valves and connectors to facilitate on-site interface connection and maintenance.

04 / SENSING

pressure monitoring

Through pressure monitoring and instrument accessories, it provides a basis for operation adjustment and on-site inspection.

05 / INTEGRATION

Base and connection

Coordinate equipment support, connection structures and pipeline layout, and reserve space for installation and maintenance.

Schematic diagram of the complete set of equipment. Water source access, steady flow compensation and supporting protection devices shall be confirmed according to the selected water supply plan and project conditions.

CONTROL IN ACTION / Online interactive experience

Get your hands on it and see every response from your water supply.

Switch water usage conditions, adjust target pressure, and experience the start, stop, and automatic protection of the pump unit.

Independent window experience ↗

02 / RESPONSIVE CONTROL

Sensing changes in water use,
Regulate water supply for each pass.

Based on pressure feedback,
Adjust operation according to actual water demand.

  1. 01 / MONITOR

    Monitor pressure

    Collect system pressure and feedback water supply status.

  2. 02 / COMPARE

    Determine needs

    Combined with the set pressure, determine the adjustment needs.

  3. 03 / ADJUST

    Frequency conversion adjustment

    Adjust the water pump frequency and coordinate the operation of the pump unit.

  4. 04 / SUPPLY

    Regulated voltage output

    Continuous feedback and adjustment as water usage changes.

Solution selection

The non-negative pressure water supply solution needs to be combined with the municipal pipe network conditions to confirm the access method, steady flow compensation and protection configuration; when water tank water supply is used, it should be designed separately based on the water storage conditions. The specific pump unit configuration and control logic are subject to the project plan.

Backpack type frequency conversion control unit and pump set structure
Backpack type frequency conversion control unit and pump set structure · Rendering diagram

03 / INTEGRATED CONTROL

control and pump sets,
Compact integration.

The backpack-type frequency conversion control cabinet is combined with the layout of the pump unit to coordinate equipment connection and operation control in a limited space.

Compact structure
Coordinate the pump set and control unit according to the size, arrangement and operating position of the equipment.
Run linkage
Pressure monitoring and frequency conversion adjustment cooperate to allow water supply operation to change according to demand.
Manage extensions
Functions such as remote monitoring, running status viewing, alarming and recording can be configured on a project-by-project basis.

EPANEL / PRODUCT PHOTOS

Get close to the device and see the real details.

Actual factory photos of complete pump sets, pipelines and control units. Click on the image to enlarge it.

16 Real product shots

Swipe left and right to browse · Click to view larger image

04 / APPLICATIONS

Respond to the water needs of different buildings.

Focusing on water supply zoning and operating conditions,
Match the appropriate water supply solution.

RESIDENTIAL

Homes and Communities

Plan the domestic water supply configuration based on building height, water use scale and water supply zoning.

PUBLIC BUILDINGS

commercial and public buildings

It is suitable for offices, hotels, schools and other scenarios to match the water demand in different periods.

INDUSTRIAL PARKS

Park and supporting facilities

Combined with the living and supporting water conditions of the park, the interface, operation and maintenance will be coordinated.

05 / PROJECT PLANNING

Starting from the water conditions, confirm the water supply configuration.

Provide the following information,
Make the connection between selection and site clearer.

Flow and pressure
Design flow, target pressure, building height and water supply zoning.
Water sources and access
Municipal water pressure, water source conditions and water tank or pipe network access methods.
Site and interface
Pump room space, water inlet and outlet diameter, power supply and maintenance access.
Operation and management
Pump set combination, control requirements and monitoring and communication configuration.

TALK TO EPANEL

Let the equipment adapt to your water supply project.

Contact EPANEL to discuss the complete water supply and control plan.

Get selection support