Open menu
EPANEL
Skip to product content

EPANEL / PRESSURE MAINTENANCE

pressure maintenance and make-up
Vacuum degassing device

Stabilize system pressure,
Let water circulate more calmly.

Serving closed heating, air conditioning and refrigeration water systems. Integrate constant pressure water replenishment, expansion buffering and on-demand vacuum degassing functions into an equipment solution that is easy to install, control and maintain.

Two major host series · Diaphragm pressure tank matching · Independent optional water replenishment tank

EPANEL constant-pressure water replenishment and vacuum degassing equipment, displaying the main unit, diaphragm pressure tank and supporting pipelines
PRESSURE MAINTENANCE SYSTEMConstant pressure water replenishment and vacuum degassing configuration · Product rendering
01 / PRESSUREpressure maintenance and make-up

Automatically replenish water according to system pressure changes

02 / EXPANSIONbloat buffer

Matching diaphragm pressure tank absorbs water volume changes

03 / DEGASSINGVacuum degassing

Degassing host circulates and separates gases in water

01 / HOW IT WORKS

Around the closed water system, coordinated regulation

Replenish water to maintain pressure, and the air pressure tank buffers expansion.
The degassing function is configured according to system requirements.

  1. Pressure changes, automatic water replenishment

    Pressure sensors monitor system pressure. When the pressure is lower than the set value, the control system starts the water replenishment pump; when it reaches the set value, it stops replenishing water to keep the system pressure within the set range.

    Applicable to both series
  2. Water expands, diaphragm buffers

    As the water temperature changes, the system water volume changes. Diaphragm air pressure tanks use the compressibility of gas to accommodate expansion water and buffer pressure fluctuations. The tank volume and pre-charge pressure are determined according to the project.

    Matching diaphragm pressure tank
  3. Cycle pressure reduction and gas separation

    The degassing host causes part of the system water to enter the vacuum degassing unit, causing dissolved gases to precipitate and be discharged under a negative pressure environment. The treated water returns to the system and is circulated for degassing.

    YP-DBTQ-GM series
Product rendering of constant pressure water replenishment equipment, showing the configuration of the water replenishment host and diaphragm air pressure tank, excluding independent water replenishment tank
PRESSURE MAINTENANCE CONFIGURATIONConstant pressure hydration type configuration diagram · Product rendering View large image ↗

02 / PRODUCT SERIES

From constant pressure hydration to constant pressure degassing

Select host functions according to system requirements,
Then match the air pressure tank, water tank and control configuration.

YP-DB-GM

Constant pressure hydration type

The constant pressure water replenishment host is equipped with a diaphragm air pressure tank to meet the water replenishment and expansion buffering needs of the closed water system.

  • Pressure monitoring and automatic water replenishment
  • Diaphragm pressure tank expansion buffer
  • The water replenishing tank is independently selected according to the project.
Communicate constant pressure water replenishment plan
Common selection range
Selection itemsYP-DB-GMYP-DBTQ-GM
Water replenishment flow0.5–10 m³/h0.5–12 m³/h
Replenishing head40–80 m40–90 m
Degassing capacityNot configured with degassing function2–30 m³/h
Matching pressure tankDiaphragm pressure tank, volume and pre-charge pressure are determined according to system calculations
water tankIndependently optional, not included in the host model
Building communicationsRS485 / Modbus optional according to project

The above is the commonly recommended range in the selection manual, and is not an arbitrary combination of all parameters or a fixed supply commitment. The actual flow rate, head, degassing capacity, pressure tank volume and control function are subject to project selection and confirmation of technical documents.

03 / EQUIPMENT & CONTROL

Host, pressure tank and control, supporting considerations

From computer room layout to daily operation,
Make the device interface and management requirements clearly connected.

Rendering of EPANEL constant pressure water replenishment equipment, showing the layout of the host and supporting equipment
EQUIPMENT CONFIGURATIONProduct configuration rendering · The specific configuration is subject to the confirmed plan

Configure devices from one system

Water replenishment pump set and pipeline
Combined with the water supply required by the system, pressure conditions and machine room space, confirm the layout of the pump unit, valves and interfaces.
Diaphragm pressure tank
Calculate the volume based on the system water capacity, operating temperature and pressure range, and confirm the pre-filling pressure and installation conditions.
Independent water tank
Select according to water supply source, water quality requirements and site conditions. The cabinet volume and interfaces are confirmed independently and are not incorporated into the host model.

CONTROL & MONITORING

Incorporate operating status into daily management

Organize controls around system pressure, makeup pump operation, and degassing cycles. During debugging, confirm the pressure settings, action logic and operating parameters based on on-site working conditions, and pay attention to the pressure and equipment status during operation.

pressure monitoringWater replenishment pump controlDegassing cycle controlCommunication optional on demand

Degassing cycle control is suitable for degassing type hosts. The specific display content, alarm items, interlocking logic and RS485/Modbus interface are confirmed according to the project configuration.

Top view configuration diagram of EPANEL vacuum degassing host and control equipment, product rendering
SYSTEM CONFIGURATIONVacuum degassing host and control equipment · Product rendering

04 / APPLICATIONS

Closed water circulation adapted to different buildings

Selection based on system conditions,
Connect HVAC design and equipment operation management.

01

central heating

For heating closed water systems, a constant pressure water replenishment and expansion buffer solution is configured based on the building height, system water capacity and temperature changes.

Heating machine room/heat exchange system
02

Central air conditioning

For air-conditioning closed water systems in commercial buildings, hotels and public buildings, equipment functions are matched according to water supply and return conditions and pressure requirements.

Commercial complex/hotel/public building
03

Refrigeration water cycle

For closed cooling water systems that require constant pressure water replenishment, the applicability and degassing configuration should be confirmed based on medium, temperature and water quality conditions.

Chilled water system/process matching

05 / PRODUCT PHOTOS

Actual photos of products and learn about equipment details

From the overall machine layout to the pump set and valves,
Browse real-life photos of company-owned equipment.

Real shots show different equipment configurations. The specific model, structure and scope of supply are subject to the project confirmation plan.

06 / PROJECT CONFIGURATION

Provide system conditions and communicate appropriate configurations

From parameters to interfaces,
Make product selection based on evidence.

System and temperature
Heating, air conditioning or refrigeration purposes; system water capacity, medium and operating temperature.
Stress and Hydration
Building height, static pressure, working pressure range, water supply flow and water source conditions.
Computer room and interface
Available space, maintenance access, pipeline connections, drainage and power supply conditions.
Function and management
Whether vacuum degassing is required, pressure tank and water tank requirements, and building communication requirements.

TALK TO EPANEL

Let every closed water system have an appropriate pressure plan.

Contact EPANEL to discuss the selection of constant pressure water replenishment and vacuum degassing equipment.

Get solution support
EPANEL / Actual product shots